Bay note 08 — Isolation and creepage on purpose

Functional vs reinforced is a winding architecture, not a sticker. How tape, margins and bobbin choice change when the barrier is mains-referenced.

Electrical turns can be perfect and the part still wrong if the barrier is wrong. Isolation is a construction sequence.

Three words that change the build

ClassWhat it means on the bobbin
FunctionalCircuit needs it; not a safety barrier
BasicOne level of protection
Reinforced / doubleMains-to-SELV style barrier — tape, margins, often triple-insulated wire

Construction levers

  • Creepage distance on the bobbin and between pin groups
  • Tape schedule between pri/sec (layers, overlap, margin tape)
  • Triple-insulated wire vs conventional + barrier tape
  • Slot / bank winding to keep pri and sec apart

What we cannot infer

Vin and Vout never tell us reinforced vs functional. A 400 V boost for a DC bus and a 230 Vac flyback to 12 V SELV are different animals with similar turns math.

What to put on the print

  • Isolation class and standard (for example IEC 62368-1)
  • Working voltage and overvoltage category if known
  • Required hipot test (for example 3 kVac / 1 min)
  • Pinout with pri/sec sides labelled

If you are unsure, write "mains-referenced primary, SELV secondary" in plain language — we will translate it into a tape schedule.